All PACMANs used to use the same ramping parameters, this meant a SUPERPACMAN (50 kW) took literally a 100 seconds to get up to its full output level. Ouch.
PACMAN has been raised to 5000 W/s with 1500 W tolerance, SUPERPACMAN to 7500 W/s with 2500 W tolerance
- output_mv
sprite: Structures/Power/Generation/portable_generator.rsi
state: portgen0
+ - type: PowerSupplier
+ supplyRampRate: 5000
+ supplyRampTolerance: 1500
- type: entity
name: S.U.P.E.R.P.A.C.M.A.N.-type portable generator
- output_mv
sprite: Structures/Power/Generation/portable_generator.rsi
state: portgen1
+ - type: PowerSupplier
+ supplyRampRate: 7500
+ supplyRampTolerance: 2500
- type: entity
name: J.R.P.A.C.M.A.N.-type portable generator